Skip to main content
All incident reports
Incident report

SonicWall tells customers to retire Gen 6 firewalls that will receive no further patches

SonicWall has urged customers to stop running its Generation 6 firewalls at the internet edge and replace them, saying the devices will not receive patches even for critical flaws. The company says attackers using automation and AI will find and exploit unsupported edge devices faster than before.

· First published

The short version

  • The warning. SonicWall says Generation 6 firewalls running SonicOS 6.x are no longer supported and will not get security fixes, including for critical vulnerabilities. It tells customers to migrate to a Gen 8 appliance running SonicOS 8.
  • The stated reason. SonicWall says attackers use automation and AI to find and exploit unsupported edge devices, and that it expects internet-facing Gen 6 firewalls to be actively targeted.
  • Interim steps. Until a unit is replaced, SonicWall advises disabling WAN management and SSL VPN, enforcing multi-factor authentication, resetting local passwords and watching logs for unusual activity.
  • Industry context. The report cites Google Mandiant's estimate that exploitation now begins about seven days before a patch on average, and Cisco Talos' finding that 23% of 2025 CVEs affect network devices.

Timeline

DateEvent
March 2026Google Mandiant's M-Trends report estimates mean time to exploit at -7 days, meaning exploitation on average begins before a patch is available.
20 NovThe Hacker News reports SonicWall's warning that Gen 6 firewalls will not receive patches and should be retired.

The warning

SonicWall urged customers still running Generation 6 firewalls to retire and replace them immediately and to stop exposing the devices at the internet edge. The affected products run SonicOS 6.x and cover small-office TZ and SOHO models, NSA and NSa appliances, NSsp and SuperMassive chassis, and the NSv virtual series.

SonicWall says the devices will not receive patches even for critical flaws, and directs customers to a Gen 8 firewall running SonicOS 8, planned with an authorised SonicWall partner. It also advises inventorying every Gen 6 unit in production and prioritising those that face the internet or provide remote access.

Why edge devices are the target

"The risk to an unsupported firewall grows every day it stays online," SonicWall said. The company said a compromised perimeter firewall gives attackers a foothold for credential theft, lateral movement and ransomware deployment, and that automation and AI let attackers find and exploit unsupported edge devices faster than before.

The report cites Google Mandiant's M-Trends report, published in March 2026, which estimated mean time to exploit at -7 days, meaning exploitation on average starts a week before a patch exists; the figure was 63 days in 2018 and -1 day in 2024. Cisco Talos' 2025 Year in Review found 23% of that year's CVEs directly affect network devices such as VPN appliances, firewalls, load balancers and routers.

Interim mitigations

For devices that cannot be replaced at once, SonicWall lists steps to reduce exposure: turn off WAN management for HTTPS, SSH and SNMP; disable SSL VPN or limit it to known source addresses; enforce multi-factor authentication on every remaining remote-access and admin account and reset local passwords; disable unused services and interfaces; and monitor logs for unusual logins, configuration changes and traffic.

What is not known yet

  • Whether any Gen 6 firewall has already been compromised, and by whom.
  • How many Gen 6 devices remain in service or reachable from the internet.
  • Whether SonicWall would make an exception and patch a critical flaw found in Gen 6 after this notice.
  • Which specific flaws or campaigns prompted the warning; no CVE is named.
  • Whether SonicWall's own systems or customers have been affected by targeting of these devices.

What to do

If you run Gen 6 firewalls

  1. Inventory every Gen 6 firewall in production and list the ones exposed to the internet or used for remote access.
  2. Stop exposing Gen 6 devices at the internet edge.
  3. Replace them with a Gen 8 firewall running SonicOS 8, planned with an authorised SonicWall partner.

If a Gen 6 unit must stay in service for now

  1. Disable WAN management for HTTPS, SSH and SNMP.
  2. Disable SSL VPN, or restrict it to known source addresses.
  3. Enforce multi-factor authentication on all remote-access and admin accounts and reset local passwords.
  4. Disable unused services and interfaces, and review logs for unusual logins, configuration changes and traffic.

For everyone else

  1. Treat any perimeter device past its support date as a high-risk exposure and schedule its replacement before support ends.
  2. Assume exploitation may begin before a patch is available when planning how quickly edge devices can be updated or removed.

Update log

  • First published.

Sources

New incident reports by email

One email a week with the reports published since the last one.

We email you about this topic only; unsubscribe any time. See our Privacy Policy.

Want us to look at your domain?